KILNHOOD & BURNER
Low thermal conductivity and abrasion resistance are important for refractories at the kiln hood and burner lead-in. Waste fuels can make chemical resistance necessary too.
Click to enlarge
Our refractory solutions are listed on the tables below:
Area / Temperature (°C) | Processing Conditions | Monolithic solutions | Brick solutions | Energy Saving brick solutions |
---|---|---|---|---|
Upper and Lower part 900- 1200°C | Abrasion Chemical attack Thermal shock | HÖGANÄS CAST /GUN LC 50 AR Severe Conditions HÖGANÄS CAST LC 60 AR HÖGANÄS CAST LC 75 AR HÖGANÄS CAST/GUN LC S10 Insulation HÖGANÄS INSUL CC 1,5L | Silox 60 Victor 60,70,80RK Severe Conditions Silox 60 Victor 80RK Insulation HÖGANÄS INSUL M E/brick HIPOR 450/brick Super 1100E Porosil 23 | Silox 60 Insulation HÖGANÄS INSUL M E/brick Porosil 23/slab |
Click to enlarge
Area / Temperature (°C) | Processing Conditions | Monolithic solutions |
---|---|---|
Burner lance 900- 1200°C | Abrasion Alkali Impact Thermal shock | HÖGANÄS CAST LC 75 AR HÖGANÄS CAST CC S10 (* Best results with 4-6% steel fiber) Steel anchors |